Variable frequency drives V810

Variable frequency drives V810

Variable frequency drives V810

Variable frequency drives V810

Variable frequency drives V810

Variable frequency drives V810

The V810 series inverters are designed for the most demanding and most complicated professional applications. These are vector frequency converters with a wide range of applications. They handle overloads of up to 180% for 3 seconds and overloads of 150% for 60 seconds. It is the highest class of frequency converters, which are produced in series up to 1000kW. They are destined to handle a huge load. A large performance range with different drive configurations and many additional options allows the use of a single platform for a variety of requirements. Our inverters are used in all industries from simple to the most demanding applications.

Variable frequency drive V810 – Functions

– Power supply to the frequency converter with 3 x 400 V AC or 3 x 690 V AC
– Frequency converter control mode is CLVC vector closed circuit, SVC vector open circuit, or V/F control
– Converter output frequency 0.01 to 3200 Hz
– V810 operates with a carrier frequency of 1 to 16 kHz
– V810 has a standard built-in brake unit up to 18.5 kW, PID, PLC
– Standard AVR, JOG, Timers, Protections
– EMS STOP immediate stop safety function
– Connection function of PTC protection or electric motor thermocontact
– Removable panel with external installation up to 50 m (by cable)
– V810 features 8 digital PNP or NPN digital inputs, including 1 high-speed 100 kHz pulse input; 2 analog inputs -10 / +10 V; 0-10 V and 4-20 mA (or 0 to 20 mA).
– The outputs are 1 digital – high speed, 2 analog and 2 relay
– RS 485 MODBUS physical interface built in as standard
– MODBUS RTU communication interface; PROFIBUS-DP
– Built-in port for connecting PG cards (encoder, resolver, etc.)
– Standards EN/IEC 61800-3: 2017; C1 which is suitable for 1. environment; EN/IEC 61800-3: 2016; C2 which is suitable for 1. environment;
– The model is produced in power series up to 1 MW

The VECTOR V810 is the latest range of frequency inverters for demanding industrial applications. They can operate at an output frequency of up to 3200 Hz. The V810 series has vector control with feedback, no feedback and V/F control. The basic equipment includes a built-in PID, PLC, AVR, JOG, TC, EMS safety stop system, input for connection of PTC protection or electric motor thermal contact, MODBUS communication, etc. Options: PROFIBUS DP, PG card, …Standards IEC 61800-5-1, IEC 61800-3 (Environment 1 and 2, Category C2). The V810 has 8 digital inputs, including 1 high-speed 100 kHz pulse; 2 analog inputs – 10 V / + 10 V, 4 – 20 mA, 0 to 10 V. It has 1 high-speed digital output, 2 relay outputs and 2 analog outputs. The converter panel is removable with the possibility of external installation up to approx. 50 m by cable. The V810 frequency inverter is factory-set and in the basic application, only the correct wiring and the START command are sufficient.

Frequency inverter V810 – heavy industry:

– automobile industry
– mining industry
– chemical industry
– energetics
– metallurgy
– aviation industry
– construction
– engineering

Frequency inverter V810 – light industry:

– electrotechnical industry
– food industry
– textile industry

Variable frequency drives

Item VFD V810
Power supply Input voltage range:
1 x 230 V AC ± 15%
3 x 400 V AC ± 15%
3 x 690 V AC ± 15%
Power frequency range: 47 to 63 Hz
Control mode V/F control; Senseless flux vector control (SFVC); Closed-loop vector control (CLVC)
Maximum frequency Vector control: 0-320 Hz; V/F control: 0-3200 Hz
Carrier frequency 1,0-16,0 kHz; The carrier frequency is automatically adjusted based on the load features.
Input frequency resolution Digital setting: 0,01 Hz / Analog setting: 0,025% of maximum frequency
Startup torque G type: 0,5 Hz/150% (SFVC); 0,5 Hz/180% (CLVC); P type: 0,5 Hz/100% (V/F)
Speed range 1:100 (SFVC); 1:1000 (CLVC)
Speed stability accuracy ± 0,5% (SFVC); ± 0,02% (CLVC)
Torque control ± 5% (CLVC)
Overload capacity G type: 60s for 150% of the rated current, 3s for 180% of the rated current.
P type: 60s for 120% of the rated current, 3s for the 150% of the rated current.
Torque boost Auto boost / Customized boost 0,1%-30,0%
V/F curve Straight – line V/F curve; Multi-point V/F curve N-power V/F curve (1,2-power, 1,4-power, 1,6-power, 1,8-power, square)
V/F separation Two types: complete separation; half separation.
Ramp mode Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0,0-6500,0s
Input terminal 8 digital input terminals, one of which supports up to 100 kHz high-speed pulse input. 2 analog input terminals, one of which only supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input.
Output terminal 1 Programmable open collector output: provides 1 output terminal (open collector output or high speed pulse output); 2 relay outputs; 2 analog outputs: FOV and FOC with optional 0-20 mA (4-20 mA) or 0-10 V output
Support for multiple PG cards Support for rotating transformer PG card, differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card
DC braking DC braking frequency: 0.0 Hz to maximum frequency; Braking time: 0.0-36.0s; Braking action current value: 0.0%-100.0%
Brake unit Models up to 18,5kW have a built-in brake unit as standard.
JOG control JOG frequency range: 0,00-50,00 Hz; JOG acceleration/deceleration time: 0,0-6500,0s
Onboard multiple preset speeds It implements up to 16 speeds viac the simple PLC function or combination of X terminal states
PTC/Thermal contact Input for PTC motor protection or thermocontact protection.
Built-in PID controller It facilitates a process-controlled closed loop control system.
Automatic voltage regulation AVR It can automatically maintain a constant output voltage when the supply voltage changes.
Overvoltage/Overcurrent stall control The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent.
Torque limit and control It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode.
EMS STOP safety function Emergency stop system: In emergencies, the inverter stops immediately after EMS STOP is activated.
Rapid current limit It helps to avoid frequent over current faults of the AC drive.
High performance Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
Timing control Time range: 0,0-6500,0 minutes
Communication methods MODBUS RTU, PROFIBUS-DP
Running command source Operation panel / Control terminals / Serial communication port. You can perform switchover between these sources in various ways.
Frequency source 10 types of frequencies, given by digital analog voltage, analog current, pulse, serial port, X8, PID, can be switched in many ways.
Auxiliary frequency source There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis.
LED display It displays the parameters.
Key locking and function selection It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function.
Protection mode Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection.
EMC (Compatibility) IEC 61000-4-6; IEC 61000-4-4;IEC 61000-4-11; IEC 61000-4-5
Standards EN/IEC 61800-3: 2016; C1 which is suitable for 1. environment; EN/IEC 61800-3: 2016; C2 which is suitable for 1. environment;
Installation in the environment Install indoors, avoid direct sunlight, salt, dust, corrosive or flammable gas, smoke, steam. Resistance to chemical pollution class 3C3 EN/IEC 60721-3-3. Dust resistance 3S3 EN/IEC 60721-3-3.
Height above sea level Below 1000 meters above sea level. (reduce the power level when used above 1000 meters)
Ambient temperature -10°C ~ 40°C (reduce power level if ambient temperature is between 40°C to 50°C)
Humidity Less than 95% relative humidity, without condensation IEC 60068-2-3
Vibration Less than 5.9 m/s2 (0.6 g) IEC 60068-2-6
Storage temperature -20°C ~ 60°C